Escalator Inverter

WIN-V6E Series all-in-one inverter for escalator

 
Power range

380V,3 phases, 5.537kW

Application area

WIN-V6E is all-in-one inverter dedicated for escalator. High integration, complete function, perfect performance, easy installation and maintenance endues this inverter with very high service value.

Main feature

  • This inverter can meet all the demands of escalator control without using extra PLC and other control board.
  • All range of inverters have built-in braking unit.
  • It has phase-sequence detecting function which can achieve production of fault phase or phase loss.
  • smooth switch between mains supply and inverter. The normal switch solution has a current shock which is 10 times of the motor's rated current. The switch solution of WIN-V6E only creates 1-3 times of the motor's rated current. People has no impact feeling during switch since the inverter has speed search function.
  • calendar and memory function.
  • Automatic/manual energy-saving operation.
  • overload capability: 150%/2 minutes.
  • Modbus and CAN communication.
  • Personalized PC tuning function.
  • Perfect escalator control logic(maintenance operation, reverse input protection, star/delta start, roller shutter related function, earthquake related function, fire disaster related function, over speed protection, under-speed protection, security controller control, oiling control, handrail detection, security circuit detection).
  • Common DC bus.
  • 4 digits, eight bits display, 5 operating keys.
  • synchronous motor control/asynchronous motor control.
  • ABZ encoder for synchronous motor.
  • optional keypad for parameter copy.
  • control signal terminal is removable, convenient for installation and maintenance.
  • All signal channel has LED indicator.
  • Motor parameters self-tuning.(static and running optional)
  • 16K carrier frequency, low-noise operation.
  • built in PG card connector.
  • Meet the standard of IEC61800-3 and GB7588-2003.

 

Key

Function

PRG

Enter or exit programming status.

ENTER

Enter lower level menu or confirm data.

>> 

n editing mode, pressing this key to select the bit to be modified. In other mode, this key is used to scroll through the parameters.

Increase value or parameter.

Decrease value or parameter.

JOG

In keypad control mode, press this key to start jog operation.

RUN

Press this key to run the inverter in the mode of keypad control.

STOP

Press this key to stop or reset the inverter.


Control board layout

Terminal function table

Control terminal function description

Category

Terminal Name

Description

Function

Communication

485+

Communication port

485 differential signal positive terminal

485-

485 differential signal negative port

CAN communication

CANH

CAN communication port

CANH

CANL

CANL

COM

CAN

Digital input

X1~X32

Digital input1~32

Programmable bipolar optional input signal, CN5 jumper selection, when pin 1 and pin 2 is short connected(the side indicated with L), X1~X32 are enabled  when the input is low level; when pin 2 and pin 3 is short connected(indicated with H), X1~X32 are enabled when the input is high level.
range of input voltage:9~30 VDC
X1~X30 input impedance:4.7 kΩ
X31~X32 input impedance:1.6 kΩ
X31~X32 can be selected as high speed pulse input. Max. frequency is 50KHz.

U24

24V user power supply

This power supply is to be provided by user. it is to provide power supply for digital input terminal.

XCM

24V user power supply ground

24V user power supply ground

Transistor output

Z1~Z10

Transistor output 1~10

NPN type

U24

24V user power supply

This supply to be supplied by user

XCM

24V user power supply ground

24V user power supply ground

1A relay output

Y1/COM1

Programmable output, normally open contact, capacity of contact:250VAC /3A or 30VDC /1A

Y2/COM2

Y3/COM3

Y4/COM4

Y5~Y9/COM5

Programmable output, normally open contact, capacity of contact:250VAC /3A or 30VDC /1A is Y5-COM5Y6-COM5Y7-COM5Y8-COM5Y9-COM5

Y10~Y14/COM6

Programmable output, normally open contact, capacity of contact:250VAC /3A or 30VDC /1Arespectively is Y10-COM6Y11-COM6Y12-COM6Y13-COM6Y14-COM6

4C relay output

SK5

Programmable output, capacity of contac:250VAC /3A or 30VDC /1A
C1-NC1
normally closedC1-NO1normally openC2-NC2 normally closedC2-NO2normally open
C3-NC3
normally closedC3-NO3normally openC4-NC4normally closedC4-NO4normally open

SK6

Programmable output, capacity of contact: 250VAC /3A or 30VDC /1A
C5-NC5
normally closedC5-NO5normally openC6-NC6normally closedC6-NO6normally open
C7-NC7
normally closedC7-NO7normally openC8-NC8normally closedC8-NO8normally open

Encoder connector

24V

+24V power supply

Max. output current 250mA

CM

+24V supply ground

 

XA/XB/XZ

Encoder signal ABZ

ABZ open collector input or push-pull input

shielding

PE

Shield grounding

Shield grounding terminal


Item

Specification

Rated voltage and frequency

3 phases380V440V50Hz/60Hz

Allowed fluctuation value

Voltage fluctuation -15%~+10%Voltage imbalance rate<3%;
Frequency fluctuation, ±5%

Output voltage

3 phases0380V

Output frequency

099.99Hz

Overload

150% of rated output current, 2 minutes, 180% of rated output current, 10 seconds.

Control mode

VF control for synchronous motor and asynchronous motor; open-loop vector control for asychronous motor; closed-loop vector control for synchronous motor and asynchronous motor;

Run command source

Keypad; terminal; host PC via serial port, etc

Speed source

Panel digital reference,terminal logic reference, Host PC serial port reference.

Speed source precision

Digital setting0.01Hz

Speed source resolution
speed control precision

Open-loop vector control: ±0.5%;(25±10

Closed-loop vector control±0.05%;(25±10

Speed control range
Torque control response

Open-loop vector contro1100

Closed-loop vector control11000

Starting torque
Rated voltage and frequency

Open-loop vector control< 200ms

Closed-loop vector control<20ms

Allowed fluctuation value

Open-loop vector control180% of rated torque/0.5Hz

Closed-loop vector control200% of rated torque/0Hz

Torque control precision

Open loop ±10%closed loop±5%

Encoder voltage source output

1 port+24V/250mA

Encode connector

XAXBXZopen collector or push pull.

Programmable contact input

X1X32  totally 32 port of programmable digital input terminal, X31 and X32 can accept high-speed pulse signal.

Open-collector output

Z1Z10 10 ports totally.

Relay output(1A contact)

Y1Y14, 14 ports totallycontact capacity250V AC /3A or 30V DC /1A

Relay output(4C contact)

24C contact relay, contact capacity250V AC /3A30V DC /1A

Series communication port

RS-485 communication port 485+485-

CAN communication port

CAN communication port CANHCANL

4-digit LED display

Reference frequency, output frequency ,output voltage, output current, motor speed, switch value terminal, programming menu parameters and fault codes,etc.

Indication lamp

Unit of parameters, RUN/STOP status, input terminal indication lamp, output terminal indication lamp, fault indication lamp.

Ambient temperature

-10~+40,air temperature fluctuation is less than 0.5/Min;
An Inverter with increased capacity shall be used for environment temperature of 40
or above. The derating value of the output current of the inverter shall be 2% for each degree centigrade above 40.  Max. allowed temperature is 50

Humidity

Less than 95%RH, non-condensing

Oscillation

Less than 5.9 m/s2 (0.6g)

Storage temperature

-40~+70

Enclosure

IP20

Cooling mode

Forced air cooling