Standard Inverter

WIN-9(G\P\T\H) Standard Inverter


Power range

Voltage : 380V  Single-unit power : 1.5400kW

Application area

This series products can be used in the industry of oil, chemistry, plastics, paper making, foods, cement, printing and dyeing, metallurgy, water supply, HAVC, etc.

Main feature

  • Adopting new generation of SPWM technology, these series inverters provides rated torque at low speed. Its overload capacity is big and variable torque boost, VF curve can be preset.
  • Automatic torque boost function provides high start torque, automatic slip compensation, parameter self-learning and other advanced function enables the machine to operate with high precision
  • Perfect protection and self-analyzing system, danced technology, all-round function, convenient operation cater to the demands of energy saving and variable production processes.
  • The machine for 11-200KW output adopts enclosed structure which is anti-dust and prolongs the machine's life.
  • It is cooled by independent cooling air channel with low wind resistance. The cooling efficacy is high and the temperature rise is low.
  • The main loop with low induction and optimized layout enable the machine to fully exert its performance.
  • The front panel and keypad of the plastic-housing machine (7.5KW or less) can be detached easily, which brings great convenience to the user.
  • Adopt Hitachi 32bit motor control MCU, use advanced SVPWM control technology to optimize current wave and reduce harmonic disturbance. It has low noise and high low-frequency torque. 
  • Keyboard can display two different operating parameters, more parameters displayed and easy to transfer.
  • Four programmable output interface(two for programmable relays, two for open circuit collecting electrode output interface), multiple output for choose
  • Standard operating (RUN/STOP), two wire operating (FOR or REV/STOP), three wire operating for option. Users can choose freely.
  • Manual voltage output makes the expanded application field possible.
  • To 75kW products, internal resistor dissipating braking unit is installed to reduce users’ cost
  • Internal RS-485 interface


Key

Function

PRG

To enter the menu of functions

Esc

To exit from the data modification of function items ;
to modify the monitored contents in the lower LCD

set

To store the values while setting the parameters.
To modify the monitored contents in the upper LCD

To increase the function code or its content. To increase the function code of fault display...

To decrease the function code or its content. To decrease the function code of fault display...

for

To start the inverter by issuing a command of forward rotating in the mode of keypad control.

Stop/reset

In the event of operation: to stop the machine according to the preset deceleration time.
In the event of fault: to reset (reset is disabled while fault exists.

REV/JOG

Press this key for reverse rotation in the condition that the machine is under keypad control, and the value of F014 is 1.



Terminal function table

Category

Terminal code

Name

Function description

Control signal

COM

+24V common terminal

FOR

Forward

Effective while connected to COM

FREE

Free stop terminal

F effective while connected to COM

RST

Reset terminal

effective while connected to COM

X1X6

multi-function input terminal

Programmable multi-functional contact input

switch output signal

TA1, TB1, TC1

fault contact output1

 to fail while terminal TA and TC are connected; and terminal TB and TC are disconnected.(programmable

TA2, TB2, TC2

fault contact output2

Y1,Y2

 output signal

In the course of operationopen collector Open Collector signal output programmable

analog output signal

FM

frequency meter output

010V/100%frequencymulti-function analog value monitoring

CM

Current meter output  

05V/100%frequencymulti-function analog value monitoring

V10

Signal power supply10V

Analog +10Vpower supply

VG

Preset analog input voltage

010V/100%05V/100%

IG

Preset analog input current

420mA/100%020mA/100%

VFA, VFB

voltage feedback input signal

010V

IFA, IFB

Current feedback input signal

420mA

GND

common

supplementary power supply

+24V, COM

24Vsupplementary power supply

+24V


ITEM

Specification

output

Rated voltage output

Maximum output voltage is same as input power voltage

output of adaptive motor (kW)

1.5

2.2

3.7

5.5

7.5

11

15

18.5

22

30

37

45

55

rated output current (A)

4.0

6.0

9.6

13

17

25

32

38

45

60

75

90

110

output of adaptive motor (kW)

75

93

110

132

160

185

200

220

245

280

315

355

400

rated output current (A)

150

180

215

260

310

350

380

420

470

530

600

660

750

rating

100continuous

maximum overload current

150% 1minute180% 6minuteP series120% 1minute150% 6minuteI series150% 1minute200% 6minute

power input

voltagefrequency

T4:three phase380V  50/60HzT6three phase660/690V  50/60Hz

Allowed voltage fluctuation

10%~-15

Allowed frequency fluctuation

±5

control characteristics

control mode

SVPWM Control

Frequency control range

0400HzP series0120 HzH series02000 Hz

frequency precision

digital command±0.01%-10 +40

设定frequency analysis

digital command0.01Hzanalog command0.2Hz / 60Hz

Output frequency analysis

0.01Hz

Frequency setting signal

0+10V05V420mA020 mA

acceleration and deceleration time

0.19999minuteindependent setting of accelerating time and reaccelerating time

braking torque

additional braking resistance reaches125%

voltage/frequency characteristics

33 kinds of fixed V/F characteristics are optional and any V/F characteristics can be set

protecting functions

over voltageunder voltagecurrent clipping, over currentoverloadthermionic relayoverheatover voltage stalllow load  early warning, load shortcut.

environment

Ambient temperature

-10 +40

humidity

2090% RHno condensation

storage temperature

-20 +65

application area

indooron corrosive odor

Installation area

Altitude is less than 1000 meters, no dust, no corrosive odor, no direct sunlight

vibration

20Hz less than0.5g

protection level

IP50 for 11-200kW, IP20 for the rest

Cooling mode

Forced air cooling mode