High-performance Powerful Vector Control Inverter 1

WIN-VC high performance, powerful vector control frequency inverter


Power range

Voltage : 220V,380V,660V  Single-unit power : 0.751000kW(≥355kW is v/f control)

Application area

Suitable for high-end application area with high precision, fast response, high torque, big inertia, potential load etc.

Main feature

  • Suitable for large inertia, high accuracy, potential energy load, fast response and other high-end occasion.
  • Function of energy-saving control, speed control, slip compensation, torque compensation, torque control, null-servo control, self-learning, parameter copy and other high-end function.4 modes of control available: V/F control, V/F with PG, seedless sensor vector control, vector control with PG.
    High boosting torque at super-low speed. 150% of rated torque can be output at zero speed in the mode of closed-loop of vector control.
  • Range of speed control reaches to 1:1000.
  • precision of output frequency reaches to +/-0.01%
  • precision of speed control reaches to 0.02%
  • Mullet-functional terminal of input and output, multi-functional analog input and output, serial mode communication provide the user with various conveniences.
  • Multiple parameters online monitor function, perfect fault-analysis, alarm and protection functions maximally ensure the reliability of the machine.
  • Layout and function of keypad.

Key

Function

Local/remote

Control by keyboard/control by control -loop terminal

Menu

Options for 5 modes.

Esc

Go back to the previous page

reset

To select the displace of values

Data/enter

To define the mode, parameter and settings.

To select the parameter code or increase the setting values.

To select the parameter code or decrease the setting values.

JOG

Press this key for inching operation while the command is given by keyboard.

FWD/REV

To switch the motor's rotating direction in the condition of keyboard operation.

Run

Press this key to start the inverter in the conditional of keyboard operation, meanwhile, the light of run will turn on

stop

Press this key to stop the inviter in the conditional of keyboard operation; meanwhile, the light of stop will turn on.
In the condition of terminal control operation, to enable or disable the function of this key by choosing the parameter o2 or 02.


Terminal Function Table

category

terminal

signal function

function description

control signal

1

forward / stop

to run forward while connected, to stop while disconnected

terminal3 8are multi-function terminal

2

reverse / stop

to run reversely while disconnected, to stop while disconnected

3

external fault input

to fail while connected, to be in a normal state while disconnected

4

fault reset

to reset while connected

5

main/ministrant speed switching

Supplementary frequency command when connected

6

multi-step speed  command2

effective while connected

7

jog command

effective while connected

8

free stop

effective while connected

11

switching value input common terminal

 

analog input signal

15

speed commandpower supply+15V

speed command setting power supplyterminal+15V

33

speed commandpower supply-15V

speed command setting power supplyterminal-15V

13

main speed frequency command

010V/100%frequency-10+10V/100% +100%frequency420mA/100%frequency

14

16

supplementary frequency command

010V/100%frequency-10+10V/-100%+100%frequency

17

common terminal

terminal1314speed commandcommon terminal

12

shielding wire groundingterminal

to connect the sheath of the shielding wire

switch output signal

9

operating signal

to connect when operating

multi-function contact output

10

25

zero speed output

To connect when the frequency is the lowest

multi-fucntion analog value monitoring

26

Speed reaches to output  

to be low level within setting frequency-+2Hz.

27

terminal2526common terminal

 

18

fault contact output

t to fail while terminal 18 and 20 are connected and terminal1920 are disconnected

 

19

20

analog output signal

21

frequency meter output

010V/100%frequency

multi-fucntion analog value monitoring1

22

Analog input common terminal

 

23

current meter output  

05V/100% current

multi-fucntion analog value monitoring2

supplementary  power supply

+15V

+15V

 

GND

+15Vcommon terminal

Save level as erminal17

+24V

+24V

Common ground with terminal 1 the current is below 100mA


Item

Specification

Output

Power of adapted motor(kW)

1.5

2.2

3.7

5.5

7.5

11

15

18.5

22

30

37

45

55

75

93

110

Rated current output.(A)

380V

4.8

6.2

8

14

18

27

34

41

52

65

80

96

128

165

180

224

660690V

41

52

62

77

99

130

Power of adapted motor(kW)

132

160

185

200

220

245

280

315

355

400

500

560

630

710

800

1000

Rated current output.(A)

380V

260

302

340

380

450

470

530

605

660

750

940

1050

1200

1300

1500

1860

660690V

172

200

260

302

340

450

540

660

750

Power supllyr

Voltage,frequency

Three phase 380V (+10% -15%)50/60Hz±5%three phase 660V(+10% -15%)50 / 60Hz±5%

Control

Control mode

Current vector control, SPWM

boost torque

150% 1Hzwith PG 0Hz

Speek control range

1:100with PG 1:1000

Control precision

±0.2%with PG ±0.02%

speed response

5Hzwith PG 30Hz

Torque limitation

4 modes optional

Torque precision

±5%

Torque response

20Hzwith PG 40Hz

Frequency control range

0.1400Hz

Frequency precision(termperature fluctuation)

Digital command ±0.01% (-10 +40)analog demand±0.1% (10 25)

Frequency setting resolution

Digital command 0.01Hz; analog demand 0.03Hz/60Hz

Output frequency resolution

0.01Hz

Overload capacity

Output current rating150% 1minute

Frequency setting signal

-10V +10V0 +10V(20KΩ)420mA

Acceleration and deceleration time

0.016000 (acceleration time and deceleration time are given independently)

braking torque

20%built-in braking unit machine added with exterior braking resistor can output braking torque up to 150%

Voltage/frequency trait

1 15 fixed V/F characteristic optional and all of them can be set.

Protective function

Overvoltage, undervoltage, overload150% 1minutethermionicrelay, overheat, stall, grounding,instananeous power failure compensation.set the operating mode to be continue to operate when power recovered within 2seconds.  )、charge protectionmain loop DC voltage under50V won't be displayed

envirenment

Termerature/humidit

-10+40 / 2090%RH (on condensation)

Application situation

Indoor (no corrosive gas) altitude is not above 1000meter, no dust. No corrosive gas, not directly exposed to sunlight.

vibration

20Hz less than 0.2g

Protection class/cooling mode